Skip to content

AC Size Calculator: BTU, Tons and kW

AC size calculator: BTU per hour, tons and kW of cooling for one room, from its floor area, sun exposure, occupants and kitchen use.

Units
m

m

Sun exposure
people

The chart assumes two; each extra person adds 600 BTU/h.

Cooking heat adds 4,000 BTU/h.

Recommended cooling capacity

6,000 BTU/h0.5 ton · 1.76 kW
Room area
14 m² (150.7 ft²)
Chart capacity
6,000 BTU/h
Suggested unit size
6,000 BTU

How to use the AC Size Calculator

  1. Measure the room's length and width in meters or feet and enter them.
  2. Choose the sun exposure: heavily shaded, normal or very sunny.
  3. Enter how many people regularly use the room, and switch on Kitchen if you cook there.
  4. Read the capacity in BTU/h, tons and kW, and the standard unit size to look for.

Formula

BTU/h = Chart(A) × S + 600 × max(0, P − 2) + K; tons = BTU/h ÷ 12,000; kW = BTU/h × 0.29307107 ÷ 1,000

Where:

A
Floor area, length × width, in ft² (m² ÷ 0.09290304)
Chart(A)
ENERGY STAR capacity for that area, from 5,000 BTU/h (under 150 ft²) to 34,000 BTU/h (2,000–2,500 ft²)
S
Sun factor: 0.9 heavily shaded, 1.0 normal, 1.1 very sunny
P
People who regularly use the room; the chart already allows for two
K
Kitchen allowance: 4,000 BTU/h if the room is a kitchen, otherwise 0

The chart assumes an 8 ft (2.4 m) ceiling and ordinary insulation. Each band includes its lower edge, so exactly 150 ft² gets 6,000 BTU/h. Rooms under 100 ft² use 5,000 BTU/h; rooms over 2,500 ft² need a professional load calculation.

Worked example

A sunny 16 ft × 20 ft living room is used by three people most evenings. What size air conditioner does it need?

  1. Area = 16 × 20 = 320 ft² (29.73 m²), which falls in the 300–350 ft² band: 8,000 BTU/h.
  2. Very sunny adds 10%: 8,000 × 1.1 = 8,800 BTU/h.
  3. One person more than the two the chart assumes adds 600 BTU/h: 8,800 + 600 = 9,400 BTU/h.
  4. In tons: 9,400 ÷ 12,000 ≈ 0.78 ton. In kilowatts: 9,400 × 0.29307107 ÷ 1,000 ≈ 2.75 kW.
  5. The next standard size up is a 10,000 BTU/h unit.

The room needs about 9,400 BTU/h (0.78 ton, 2.75 kW); a 10,000 BTU/h air conditioner fits.

How many BTU a room needs

The estimate is built on the sizing chart that ENERGY STAR publishes for room air conditioners, which links floor area to cooling capacity. It works in four steps:

  1. Floor area. Length × width. A metric area is converted to square feet (1 ft² = 0.09290304 m² exactly), because the chart is written in square feet.
  2. Chart capacity. The area is matched to a band. Each band includes its lower edge, so a room of exactly 150 ft² reads as 6,000 BTU/h, not 5,000. Rooms under 100 ft² get 5,000 BTU/h, the smallest common room unit.
  3. Adjustments for sun, people and cooking, described below.
  4. Unit size. The total is rounded up to the next common capacity: 5,000, 6,000, 8,000, 10,000, 12,000, 18,000, 24,000, 30,000 or 36,000 BTU/h and up.

BTU to tons and kW

The label can state the same capacity three ways. Shops in the United States quote BTU per hour. In India, Bangladesh, Pakistan and the Middle East the same machines are sold by tonnage, so people ask for a "1 ton" or "1.5 ton AC". In Europe, the UK and Australia the rating is usually kilowatts of cooling. To convert, divide BTU/h by 12,000 for tons, or multiply by 0.29307107 and divide by 1,000 for kW. Some products list both cooling and heating capacity; compare this result with the cooling figure.

Room size chart in square feet and square meters

Floor area (ft²)Floor area (m²)BTU/hTonskW
under 150under 13.95,0000.421.47
150 to 25013.9 to 23.26,0000.501.76
250 to 30023.2 to 27.97,0000.582.05
300 to 35027.9 to 32.58,0000.672.34
350 to 40032.5 to 37.29,0000.752.64
400 to 45037.2 to 41.810,0000.832.93
450 to 55041.8 to 51.112,0001.003.52
550 to 70051.1 to 65.014,0001.174.10
700 to 1,00065.0 to 92.918,0001.505.28
1,000 to 1,20092.9 to 111.521,0001.756.15
1,200 to 1,400111.5 to 130.123,0001.926.74
1,400 to 1,500130.1 to 139.424,0002.007.03
1,500 to 2,000139.4 to 185.830,0002.508.79
2,000 to 2,500185.8 to 232.334,0002.839.96

Sun, occupants and kitchens

  • Sun. A heavily shaded room needs 10% less, a very sunny one 10% more.
  • People. The chart assumes two. Each regular occupant beyond that adds 600 BTU/h of body heat.
  • Kitchen. A stove, oven and kettle add a lot of heat, so a kitchen gets an extra 4,000 BTU/h.

Worked example: a living room in a hot climate. A living room measures 6 m × 5 m, faces west with large windows, and four people use it most evenings.

  • Area = 30 m², about 322.9 ft², in the 300 to 350 ft² band: 8,000 BTU/h.
  • Very sunny: 8,000 × 1.1 = 8,800 BTU/h.
  • Two people beyond the assumed two add 1,200 BTU/h, giving 10,000 BTU/h: about 0.83 ton or 2.93 kW.

A 10,000 BTU/h unit fits the load exactly. In much of South Asia that room would often get a 1 ton AC, which gives headroom for very hot afternoons; going to 1.5 ton would oversize it. A 3.5 m × 3 m kitchen, by contrast, is about 113 ft²: 5,000 BTU/h from the chart plus 4,000 for cooking, so 9,000 BTU/h. Cooking heat nearly doubles what a small room needs.

Ceiling height and climate

There are no inputs for these, so adjust by hand. The chart assumes about an 8 ft (2.4 m) ceiling; a 10 ft or 3 m ceiling holds roughly a quarter more air, so add capacity in proportion. The chart was written for typical US conditions, and where summer afternoons pass 40 °C (104 °F), such as the Gulf, northern India or inland Australia, many installers add 10% to 20%. Big west-facing windows, a top-floor room under an uninsulated roof or a room full of computers add load too. An oversized unit is no fix: it cools fast, switches off before removing moisture and leaves the room cold and clammy.

Assumptions and limits

The result covers one room up to 2,500 ft² (about 232 m²), with ordinary insulation and a moderate climate. It does not estimate heating, and it does not account for insulation levels, window area, air leaks or altitude. Adding up room results does not give a central-system size. For a whole house, central air or any room with unusual heat gains, ask a qualified installer for a full load calculation, such as ACCA Manual J in the United States.

Frequently asked questions

How many BTU do I need for a 12x12 room?

A 12 ft × 12 ft room is 144 ft² (13.4 m²), which falls in the ENERGY STAR band under 150 ft²: 5,000 BTU/h for a normal room with up to two people. A very sunny room needs 5,500 BTU/h, so a 6,000 BTU/h unit. If the room is a kitchen, add 4,000 BTU/h. Each extra regular occupant beyond two adds 600 BTU/h.

How many BTU per square foot for cooling?

Roughly 20 BTU/h per square foot for a typical room with an 8 ft ceiling, which is what the ENERGY STAR chart works out to in its middle bands. Small rooms need a little more per square foot and large ones a little less, so use the chart rather than a flat multiplier.

How many tons of AC per square foot?

There is no single ratio, but the ENERGY STAR chart gives 12,000 BTU/h (1 ton) to rooms of 450 to 550 ft² (41.8 to 51.1 m²) and 18,000 BTU/h (1.5 ton) to rooms of 700 to 1,000 ft² (65 to 93 m²). In a very sunny room or a hot climate, the same unit covers less floor area.

What size AC for 1500 sq ft?

For a single open space of 1,500 ft² (139.4 m²), the chart gives 30,000 BTU/h, which is 2.5 tons or about 8.79 kW, before sun, occupant and kitchen adjustments. A 1,500 ft² house is different: rooms peak at different times and ducts lose capacity, so a whole-home system should be sized with a full load calculation such as ACCA Manual J.

What does AC tonnage mean?

One ton of cooling is 12,000 BTU per hour, the heat needed to melt one short ton of ice in 24 hours. So a 1 ton AC is 12,000 BTU/h (about 3.52 kW), a 1.5 ton AC is 18,000 BTU/h and a 2 ton AC is 24,000 BTU/h. It has nothing to do with the unit's weight.

Is a bigger air conditioner better?

No. An oversized unit cools the air quickly and switches off before it has removed much moisture, leaving the room cold and clammy, and the frequent on-off cycling wastes energy and wears the compressor. Choose the smallest size that meets the calculated load.

Last updated: