Skip to content

Dilution Calculator with Percentages (C₁V₁ = C₂V₂)

A dilution calculator with percentages, molarity, mg/mL, ppm or X units: find the stock volume, the solvent to add, the final concentration and the dilution factor.

Solve for

Use the same kind of unit for C₁ and C₂.

Stock volume (V₁)

10 mLV₁ = C₂ × V₂ ÷ C₁
In m³
0.00001 m³
In L
0.01 L
In cm³
10 cm³
Diluent (solvent) to add
90 mL
Dilution factor
10×

How to use the Dilution Calculator

  1. Under Solve for, choose the unknown: stock concentration, stock volume, final concentration or final volume.
  2. Enter the other three values. Give C₁ and C₂ the same kind of unit (both molar, both mg/mL, both percent).
  3. Volumes can use different units; pick the unit you want for the answer.
  4. Read the stock volume, the diluent to add and the dilution factor, then make up the solution.

Formula

C₁ × V₁ = C₂ × V₂

Where:

C₁
Concentration of the stock solution (e.g. M, mM, mg/mL, %, X)
V₁
Volume of stock solution to take (e.g. mL, µL, L)
C₂
Concentration you want after dilution, in the same kind of unit as C₁
V₂
Total final volume after adding the diluent

The amount of solute does not change when you add solvent, so C₁V₁ = C₂V₂. The diluent to add is V₂ − V₁, which assumes volumes are additive (accurate for dilute aqueous solutions). The dilution factor is V₂ ÷ V₁ = C₁ ÷ C₂.

Worked example

You need 250 mL of 0.5 M sodium chloride and have a 2 M stock solution. How much stock and how much water do you need?

  1. Rearrange for the stock volume: V₁ = C₂ × V₂ ÷ C₁.
  2. V₁ = 0.5 M × 250 mL ÷ 2 M = 62.5 mL.
  3. Diluent to add = V₂ − V₁ = 250 − 62.5 = 187.5 mL of water.
  4. Dilution factor = 250 ÷ 62.5 = 4×.

Measure 62.5 mL of the 2 M stock and make it up to 250 mL with water (about 187.5 mL).

The dilution equation C₁V₁ = C₂V₂

Diluting a solution means adding more solvent, usually water, to lower its concentration. The amount of dissolved substance stays exactly the same; it is simply spread through a larger volume. Laboratories keep concentrated stock solutions because they take up less space and last longer, then dilute small portions to the working concentration each experiment needs. The same arithmetic applies to a cleaning concentrate, a fertilizer feed or the standards for a calibration curve.

Because the solute does not change, concentration times volume before dilution equals concentration times volume after. Rearranged for each unknown:

  • V₁ = C₂ × V₂ ÷ C₁ (the most common question: how much stock?)
  • V₂ = C₁ × V₁ ÷ C₂ (how far can I dilute this amount?)
  • C₂ = C₁ × V₁ ÷ V₂ (what concentration did I end up with?)
  • C₁ = C₂ × V₂ ÷ V₁ (what was the stock, working backward?)

Volumes must match when you work by hand, but the tool converts µL, mL, L and US units for you.

Diluting percent solutions

Percent comes in three kinds: weight per volume (w/v, grams per 100 mL), volume per volume (v/v, common for alcohols) and weight per weight (w/w, common for concentrated acids). The equation does not care which one you use, as long as C₁ and C₂ are the same kind. It cannot convert between them, because that needs the density of the solution.

Example: make 100 mL of 70% ethanol (v/v) from 95% ethanol.

  1. V₁ = 70 × 100 ÷ 95 ≈ 73.68 mL of the 95% stock.
  2. Make it up to 100 mL with water. That takes slightly more than 26.32 mL, because ethanol and water shrink a little when mixed, so fill to the mark rather than measuring the water separately.
  3. The dilution factor is 95 ÷ 70 ≈ 1.36×.

Molarity, mg/mL and ppm

Molar units (M, mM, µM, nM), mass per volume (g/L, mg/mL, mg/L, µg/mL), percent, ppm and fold (X) are separate families. Within a family the tool converts freely; across families it refuses, because turning molarity into mg/mL needs the solute's molar mass.

Example: ampicillin is commonly stored at 100 mg/mL and used at 100 µg/mL. How much stock goes into 500 mL of media?

  1. Choose mg/mL for C₁ and µg/mL for C₂; both are mass per volume. In one unit, the stock is 100,000 µg/mL.
  2. V₁ = 100 × 500 ÷ 100,000 = 0.5 mL, or 500 µL.
  3. Dilution factor = 500 ÷ 0.5 = 1,000×.

The stock is so small next to the final volume that you can add it straight to 500 mL of media; the extra 0.5 mL changes the result by only 0.1%.

Dilution factor and ratios

The result shows the dilution factor as N×, where N = V₂ ÷ V₁ = C₁ ÷ C₂. Ratios are less clear. In most labs "1:N" means 1 part in N parts total, but on cleaning products and in some older protocols it means 1 part stock plus N parts water. The tool takes concentrations, not ratios, so convert first:

Written ratioFactor if "in N total"Stock in 100 mLFactor if "plus N water"Stock in 100 mL
1:22×50 mL3×33.33 mL
1:44×25 mL5×20 mL
1:1010×10 mL11×9.09 mL
1:100100×1 mL101×0.99 mL

For very large factors, a serial dilution repeats a smaller step: four 10× steps take 1 M down to 0.1 mM (10,000×) without pipetting tiny volumes. Run the tool once per step.

Common mistakes

  • Treating V₂ − V₁ as the final volume. V₂ is the total after mixing, not the amount of water added.
  • Swapping C₁ and C₂. If the final concentration is higher than the stock, the tool warns that you would be concentrating, not diluting.
  • Pipetting below your instrument's range. Measuring 12.5 µL precisely needs a micropipette; otherwise scale V₂ up or dilute in steps.

Lab safety

When diluting concentrated acids, especially sulfuric acid, always add acid to water, slowly and with stirring, never water to acid. The heat released can make water boil and spatter corrosive liquid. Wear eye protection and gloves, work in a fume hood for volatile reagents, and follow your institution's safety data sheets. The tool handles the arithmetic only; it does not replace a validated protocol. Mixing two solutions of different strengths and making a solution from powder are not covered.

Frequently asked questions

How do I dilute a solution to a specific concentration?

Use C₁V₁ = C₂V₂ and solve for the stock volume: V₁ = C₂ × V₂ ÷ C₁. To make 100 mL of 0.1 M from a 1 M stock, V₁ = 0.1 × 100 ÷ 1 = 10 mL. Take 10 mL of stock and add solvent until the total volume is 100 mL, not until you have added 100 mL.

How do I calculate dilution factor?

Divide the final volume by the stock volume: dilution factor = V₂ ÷ V₁. Diluting 10 mL to 100 mL is a 10× dilution. Be careful with ratio notation: 1:10 usually means 1 part in 10 parts total (10×), but some labs and cleaning-product labels use it to mean 1 part plus 10 parts diluent (11×).

How do I calculate dilution factor from concentration?

Divide the stock concentration by the final concentration: dilution factor = C₁ ÷ C₂. Going from 2 M to 0.5 M is a 4× dilution, and from 95% to 70% is about 1.36×. Both concentrations must be in the same unit, and the factor matches V₂ ÷ V₁ because the amount of solute stays the same.

How do I dilute 10X to 1X?

Treat X as the concentration unit, which the calculator offers. For 500 mL of 1X buffer, V₁ = 1 × 500 ÷ 10 = 50 mL of 10X stock, made up to 500 mL with water (450 mL). Any 10X to 1X dilution uses one part stock to nine parts water.

What is C1V1 = C2V2 called, and how does M1V1 = M2V2 work?

It is usually called the dilution equation or dilution formula. It works because adding solvent does not change the amount of solute, so concentration × volume is the same before and after. M1V1 = M2V2 is the same equation written with molarity (M); C1V1 = C2V2 works with any concentration unit, as long as both sides use the same one.

Can I use C1V1 = C2V2 with molar and mass units together?

Not directly. Convert one concentration first using the solute's molar mass (g/L = mol/L × g/mol). The calculator blocks mixed families such as M and mg/mL, and percent with molar, to prevent that mistake. Mass-per-volume units such as mg/mL and µg/mL can be mixed freely.

Last updated: